BWRMN - VARFLO & VARFIL SLEEVINGS

  • MSDS: BWRMN
  • Manufacturer: VARFLEX CORP
  • Product Name: VARFLO & VARFIL SLEEVINGS
  • National Stock Number: 5970-01-339-5620
Product Identification

Product ID:VARFLO & VARFIL SLEEVINGS
MSDS Date:06/25/1993
FSC:5970
NIIN:01-339-5620
MSDS Number: BWRMN

Responsible Party
VARFLEX CORPORATION
512 WEST COURT STREET
ROME, NY 13440
US

Emergency Phone: 315-336-4400

Info Phone: 315-336-4400

Preparer: DIANE TERRY

Cage: 79074

Contractor
VARFLEX CORPORATION
ROME, NY 13440 US

Telephone: 315-336-4400

Cage: 79074

Ingredients

FIBROUS GLASS

OSHA PEL 5 MG/M3 (RESP. DUST)

ACGIH TLV: 10 MG/M3 (RESP DUST)


POLYVINYL CHLORIDE RESIN


10,10-OXYBISPHENOXARSINE (PHENOXARSINE, 10,10'-OXYDI-

CAS: 58-36-6

RTECS: SP6800000

Fraction By Weight: <0.1%


ANTIMONY OXIDE

CAS: 1309-64-4

RTECS: CC5650000

Fraction By Weight: <2.5%

OSHA PEL 0.5 MG/M3 (SB)

ACGIH TLV: 0.5 MG/M3 (SB)

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


TRIBASIC LEAD SULPHATE

Fraction By Weight: <1.5%

OSHA PEL 0.05 MG/M3 (PB)

ACGIH TLV: 0.05 MG/M3 (PB)

Hazards

Routes of Entry: Inhalation:NO Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ACUTE: CONTACT MAY CAUSE MECHANICAL
IRRITATION OF SKIN & EYES. INGESTION IS UNLIKELY TO OCCUR. NO DATA
FOUND FOR INHALATION. CHRONIC: NONE.
Explanation of Carcinogenicity:ANTIMONY OXIDE IS LISTED AS AN IARC 2B
SUSPECTED (INSUFFICIENT HUMAN DATA) CARCINOGEN.
Effects of Overexposure:YEES: REDNESS, ITCHING, TEARING, DISCOMFORT OR
PAIN. SKIN: REDNESS, ITCHING, DISCOMFORT.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:SKIN-REMOVE CONTAMINATED CLOTHES. WASH WITH SOAP & WATER. IF
IRRITATION PERSISTS, SEE A DOCTOR. EYES-FLUSH WITH LOTS OF WATER
FOR 15 MINUTES; LIFTING LIDS. GET MEDICAL ATTENTION IF SYMPTOMS
PERSISTS.

Fire Fighting

Extinguishing Media:WATER FOG, CARBON DIOXIDE, DRY CHEMICAL, FOAM.
Fire Fighting Procedures:NONE SPECIFIED BY MANUFACTURER. DLA-HMIS: WEAR
SELF-CONTAINED BREATHING APPARATUS AND FULL PROTECTIVE GEAR.
Unusual Fire/Explosion Hazard:HYDROGEN CHLORIDE GAS LIBRATED DURING
COMBUSTION AND AT 550F 0R GREATER.

Accidental Release

Spill Release Procedures:NONE SPECIFIED BY MANUFACTURER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:FOR PROLONGED PERIODS, STORE IN
ABSENCE OF DIRECT SUNLIGHT. IF IN CONTACT WITH SENSITIVE SKIN, USE
GLOVES.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

Exposure Controls

Respiratory Protection:NONE NORMALLY REQUIRED.
Ventilation:USE ADEQUATE MECHANICAL VENTILATION OR LOCAL EXHAUST TO
MAINTAIN EXPOSURE BELOW TLV(S).
Protective Gloves:USE WITH SENSITIVE SKIN-WORK/LEATHER.
Eye Protection:NONE NORMALLY REQUIRED.
Other Protective Equipment:NONE NORMALLY REQUIRED.
Work Hygienic Practices:WASH & SHOWER AT THE END OF WORKDAY.
Supplemental Safety and Health

Chemical Properties

HCC:N1
Spec Gravity:1.3
Solubility in Water:NEGLIGIBLE
Appearance and Odor:CYLINDRICAL FIBERGLASS BRAID, PVC COATED WITH A
SLIGHT ODOR.

Stability

Stability Indicator/Materials to Avoid:YES
SILVER, COPPER.
Stability Condition to Avoid:HIGH TEMPERATURES 500F OR GREATER PRODUCES
HYDROGEN CHLORIDE VAPORS.
Hazardous Decomposition Products:HYDROGEN CHLORIDE
Conditions to Avoid Polymerization:WILL NOT OCCUR.

Disposal

Waste Disposal Methods:PRIMARY METHOD IS IN A MUNICIPAL OR SANITARY
LANDFILL. DISOSE OF IN ACCORDANCE WITH LOCAL, STATE AND FEDERAL
REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their